This ATEX dust level sensor is designed to detect unusual dust deposits on the bottom inside the BADA-VEX ATEX non-return valve which could lead to functioning issues.
The standard BADA-VEX non-return valves are foreseen with a brass M12 plug on the underside of the body designed to fit this sensor.
NAMUR sensors must be used with switching amplifiers approved for this intrinsic safety mode according to EN 60079-11:2012.
| Description | Item ID |
|---|---|
| Dust level capacitive sensor M12 for BADA-VEX St2 (ATEX zone 20 - II1D) | NCEA000002 |