The RVD rotary valves is developped for applications under a filter. The universal flanges on the top and underside of the valve are drilled according to PN flange standards.
The standard execution is desiged to handle products with a max. temperature of 70 °C and a maximum pressure difference of 0,5 bar. the rotary valves are resistant to a explosion pressure surge in executions according to ATEX 2014/34/CE norm up to Group II Category 1D/-, or in flameproof execution category St.2.
These rotary valves also follow the following harmonized standards:
– EN 15089:2009
– EN 13463-1:2009
– EN 13463-5:2011
| Description | Item ID |
|---|---|
| Cast iron rotary valve RVD2-X3-06_ATEX Component as 'EQUIPMENT' category according to BVS 03 ATEX H 044X certificate, II1/- D Ex Zone 20 inside/Safe area outside (2014/34/EU), with 6 adjustable blades in Polyuréthane, not flameproof. Gear motor Nord 0,37 kW, 27 rpm. Inlet dimensions: 250x250. RAL 9006 | JCBA000001 |
| Cast iron rotary valve RVD2-X3-08_Protectiv system according to ATEX 2014/34/EU norm, Group II. Category II1/- D Ex, Zone 20 inside/Safe area outside, with 8 adjustable blades in Polyuréthane, flameproof and explosion pressure shock resistant up to 2 bars with dust class ST2. Gear motor Nord 0,37 kW, 27 rpm. Inlet dimensions: 250x250. RAL 9006 | JCBA000002 |